|
EXAMPLES TO ILLISTRATE
THE DIFFERENCES BETWEEN THE 1997 UBC AND THE
2002 MSJC CODE
PART I: OUT-OF-PLANE
LOADS ON MASONRY WALLS
INTRODUCTION
The
previous issue of "Masonry Chronicles"
highlighted the differences between the masonry
design provisions of the 1997 Uniform
Building Code (1997 UBC) and Building
Code Requirements for Masonry Structures: ACI
530-02/ASCE 5-02/TMS 402-02 by the Masonry
Standards Joint Committee (MSJC Code). This
issue will continue with that theme by providing
examples for the design of masonry walls for
out-of-plane loads. The examples will be done
using both the method prescribed by the 1997 UBC
and the method prescribed by the MSJC Code with
major differences pointed out in the MSJC
Example.
The examples used in this
issue are modified from examples used in the
Seismic Design of Masonry Using the
1997 UBC, by Ekwueme and Uzarski.
WORKING STRESS
DESIGN
The Working Stress Design
procedures for out-of-plane loading change very
little between the 1997 UBC and the MSJC Code.
Ultimately, these changes have little effect on
design.
STRENGTH
DESIGN
For this example a 29'-0"
high wall constructed of solid grouted 10"
(nominal) concrete masonry units ( )
will be designed for out-of-plane loading. The
vertical reinforcing steel consists of
two-layers of #5 @ 16" o.c. The example wall is
shown in Figures 1 and 2. The factored loads
are given by:
FIGURE 1 EXAMPLE
WALL

FIGURE 2 CROSS
SECTION OF EXAMPLE WALL
Strength Design for
Out-of-Plane Loads Using the 1997
UBC
The eccentricity of the
roof load, as shown in Figure 1, is given
by:
For service
loads,
Equation
(8-19)
Therefore, the wall will
be designed with the procedures in Section
2108.2.4.4. The moment at the mid-height of the
wall is given by the following equation, which
accounts for the secondary moments caused by
wall displacement:
Equation (8-20)
Where is the deflection
at mid-height due to factored loads. The
deflection at mid-height depends on whether the
wall moment has exceeded the cracking limit
state, as specified in Section 2108.2.4.6 of the
1997 UBC. Thus, the cracking properties of the
cross-section are calculated as follows.
The modulus of rupture of
fully grouted hollow-unit masonry is given
by:
Equation (8-31)
The cracking moment
strength is equal to:
Equation
(8-30)
The gross moment of
inertia is equal to:

Neglecting the effect of
the compression steel, the depth of the
compressive stress block is:
Equation
(8-25)
The depth of the neutral
axis is given by:

The cracked moment of
inertia is calculated using the formula
recommended by the Structural Engineers
Association of Southern California
(SEAOSC):

The effective area of
reinforcing steel, which includes the influence
of the axial compression force on the wall, is
given by:
Equation (8-24)
Thus,

The ultimate moment in the
wall depends on the deflection of the wall.
Since the deflection can not be initially known,
an iterative procedure is used to determine both
the ultimate moment and the deflection.
For the first iteration,
an assumption of
for the mid-height of the wall is made. Thus,
the ultimate moment at the mid-height of the
wall is equal to:
Equation (8-20)

Since
the wall deflection is calculated
using:
Equation (8-29)
Using the calculated
ultimate moment and displacement values from the
previous iteration, the displacements quickly
converge:
Iteration 2:
Iteration 3:
Since
the process has converged and .
The design must now be checked against the
moment capacity

Equation (8-22)
Ignoring the contribution
of the compression steel, the moment capacity of
the wall, with the reinforcement at the face of
the wall, is given by:

Thus, the design is
adequate for out-of-plane loads.
The equation for
differs from Equation (8-23) in the 1997 UBC.
This is because the code equation is only
applicable to cross-sections with the
reinforcement in the center of the
wall.
Strength Design for
Out-of-Plane Loads Using the MSJC
Code
The eccentricity of the
roof load is given by:
For service
loads,
Therefore, the wall will
be designed with the procedures in Section
3.2.5.4. Note that the stress cut-off level for
P-D effects differs from that used in the 1997
UBC.
The moment at the
mid-height of the wall is given by the following
equation, which accounts for the secondary
moments caused by wall displacement:
Equation (3-24)
This equation is similar
to Equation (8-20) from the 1997 UBC. The
deflection at mid-height, ,
is due to factored loads. The deflection at
mid-height depends on whether the wall moment
has exceeded the cracking limit state, as
specified in Section 3.2.5.6 of the MSJC Code.
We must therefore calculate the cracking
properties of the cross-section.
The modulus of rupture of
fully grouted hollow-unit masonry, with the
direction of the flexural tensile stress normal
to the bed joints, is given by Table 3.1.7.2.1
as:
This value differs from
that given by Equation (8-31) from the 1997 UBC.
Thus, the cracking moment strength is equal
to:
Equation (3-32)
The gross moment of
inertia is equal to:

Neglecting the effect of
the compression steel, the depth of the
compressive stress block is:
Equation
(3-28)
The depth of the neutral
axis is given by:

Note that the masonry
compressive stress block provided by Section
3.2.2(g) in the MSJC code is smaller that that
allowed in Section 2108.2.1.2 of the 1997
UBC.
The cracked moment of
inertia is calculated using the formula
recommended by the Structural Engineers
Association of Southern California
(SEAOSC):
The effective area of
reinforcing steel, which includes the influence
of the axial compression force on the wall, is
given by:

Thus,

The ultimate moment in a
wall depends on the deflection of the wall.
Since the deflection can not be initially known,
an iterative procedure is used to determine both
the ultimate moment and the deflection. For the
first iteration, an assumption of
for the mid-height of the wall is made. Thus,
the ultimate moment at the mid-height of the
wall is equal to:
Equation (3-24)

Since
the wall deflection is calculated
using:
Equation (3-31)
Per Section 1.8.2.2.1 of
the MSJC Code:
for concrete masonry
This results in an
increase in stiffness of 20% over that provided
by the 1997 UBC.
Using the calculated
displacement value from the previous iteration
the displacements quickly converge:
Iteration 2:
 
Iteration 3:
Since
the process has converged and .
The design must now be
checked against the moment capacity

Equation (3-26)
Per Section 3.1.4.1 the
strength reduction factor, ,
for combinations of flexure and axial load in
reinforced masonry shall be taken as 0.9. This
represents an increase in capacity over the 1997
UBC where
=0.8 for walls with unfactored axial load of
0.04f'm or less.
Ignoring the contribution
of the compression steel, the moment capacity of
the wall with the reinforcement at the face of
the wall is given by:

Thus, the design is
adequate for out-of-plane loads.
The equation for differs
from Equation
(3-27) in the MSJC Code because the code
equation is only applicable to cross-sections
with the reinforcement in the center of the
wall.
Due to the higher
stiffness, the smaller compression block, and
the larger strength reduction factor allowed by
the MSJC Code the wall design for the MSJC Code
allows the designer to use less reinforcement
than that allowed by the 1997 UBC.
The following example
redesigns the wall using 2-layers of #6 @ 32"
o.c. (As = 0.17
in2)
Neglecting the effect of
the compression steel, the depth of the
compressive stress block is now:
Thus, the depth of the
neutral axis is given by:
Since,
Thus,
For the first iteration,
an assumption of
for the mid-height of the wall is made. Thus,
the ultimate moment at the mid-height of the
wall is equal to:

Since
the wall deflection is calculated
using:

Iteration 2:

Iteration 3:

Since
the process has converged and .
Design check:
 
Again ignoring the
contribution of the compression
steel:

Thus, for this example,
optimizing the out-of-plane wall design using
the MSJC Code allows the designer to use about
20% less steel than when the wall is designed
using the procedures from the 1997 UBC.
CONCLUSIONS
There is little difference
between the design methodologies in the 1997 UBC
and the MSJC Code. However, the MSJC Code
allows for a stiffer masonry section and a
larger strength reduction factor than that
allowed by the 1997 UBC. These factors combine
such that a wall designed using the MSJC Code
requires less flexural steel than one designed
using the 1997 UBC.
The next issue of "Masonry
Chronicles" will provide examples to highlight
the differences in in-plane design between the
1997 UBC and the MSJC Code.
This issue of "Masonry
Chronicles" was written by Melissa Kubischta of
Hart-Weidlinger.
"Masonry Chronicles" is a
publication of the Concrete Masonry Association
of California and Nevada. Reproduction is
expressly prohibited without written permission
from CMACN.
Please contact the
Association Office, with any comments or
suggestions for future issues.
Additional "Masonry
Chronicles" can be seen on the CMACN web site at
http://www.cmacn.org.
|
CMACN
IS PROUD TO ANNOUNCE OUR NEW
EXECUTIVE DIRECTOR, PAUL D.
BAMBAUER
|
|

Paul D.
Bambauer, Executive Director, Concrete
Masonry Association of California and
Nevada (CMACN)
|
The Concrete
Masonry Association of California and
Nevada announces the appointment of
Paul Bambauer as the new Executive
Director of the Association. Paul joins
the CMACN with 20 years in the cement
and concrete products industry working
in financial accounting,
administration, sales and marketing.
Most recently, Paul has been consulting
in the strategic market development
areas for various concrete wall
systems, and prior to consulting, was
Western Region Vice President of Sales
for Southdown Cement, covering the
California, Arizona and Nevada markets.
As Southdown's representative on
various market development boards and
committees within the National Concrete
Masonry Association, Portland Cement
Association and local product promotion
groups, Paul held leadership positions
in most areas of product promotion and
has a broad range of experience. He
earned a Bachelor of Science in
Business Administration from the
University Of Arizona in Tucson in
1977.
CMACN believes
Paul's promotional and administrative
skills will provide new opportunity and
direction for CMACN marketing
activities.
Paul may be
contacted at Paul@cmacn.org
or (714) 504-4497.
|
|